Hitachi HH0-110 Prüfungsthemen:
| Abschnitt | Ziele |
|---|---|
| Datensicherung | - Konzepte für Datensicherung und Wiederherstellung - RAID-Stufen und Datenredundanz |
| Speichervirtualisierung | - Überblick über virtuelle Speichersysteme - Dünnbereitstellung und Speicherpools |
| Überblick über die Speicherlösungen von Hitachi | - Überblick über die Unternehmensspeicherplattformen von Hitachi - Funktionen für Datenverwaltung und Effizienzsteigerung |
| Grundlagen der Speichertechnik | - Komponenten und Architektur von Speichersystemen - Zentrale Speicherkonzepte (Block, Datei, Objekt) |
| Speichervernetzung | - Grundlagen von SAN (Grundlagen von Fibre Channel) - NAS-Konzepte und Protokolle zur Dateifreigabe |
Hitachi Data Systems Storage Foundations - Enterprise HH0-110 Prüfungsfragen mit Lösungen
1. Hitachi Universal Replicator replicates data between which arrays?
A) Hitachi USP V and Hitachi AMS2300
B) Hitachi VSP and heterogeneous arrays
C) Hitachi VSP and Hitachi USP V
D) Hitachi USP V and Hitachi 9900V
2. You wish to virtualize three external devices on a VSP using Universal Volume Manager. Which parameter should you consider modifying to avoid high cache write pending?
A) I/O Suppression Mode
B) Cache Mode
C) Path Mode
D) Priority Mode
3. A customer has two AMS2100 systems attached as external storage to a VSP. After attaching a third AMS2100 to the VSP, they are unable to discover any new capacity. What is causing the problem?
A) The External storage license on the AMS2100 has been exceeded.
B) The Basic Operating System licensed capacity has been exceeded.
C) Some of the AMS2100 volumes are larger than 4 TB.
D) The Tiered Storage Manager licensed capacity has been exceeded.
4. One of your customers used Universal Volume Manager (UVM) to virtualize their heterogeneous storage systems attached to a VSP as external storage. Which two UVM tasks were performed during the virtualization process? (Choose two.)
A) External ports were set on the VSP to connect to the external storage systems.
B) Target ports were set on the VSP to connect to the external storage systems.
C) A UVM discovery of the external target ports was performed.
D) External volumes on the external storage were mapped as Open-9 emulations.
5. A customer is using Hitachi Universal Replicator as a disaster recovery solution. The replication traffic is increasing, requiring more journal capacity. How can the journal capacity be increased?
A) Suspend the pairs and add Open-V LDEVs to the Journal Group.
B) Dynamically add Open-V LDEVs to the Journal Group.
C) Suspend the pairs and add 3390-3 LDEVs to the Journal Group.
D) Dynamically add 3390-3 LDEVs to the Journal Group.
Fragen und Antworten:
| 1. Frage Antwort: C | 2. Frage Antwort: B | 3. Frage Antwort: B | 4. Frage Antwort: A,C | 5. Frage Antwort: B |






1106 Kundenbewertungen