IBM Assess: IBM TRIRIGA Application Platform V3.2.1 Application Development A2010-597 Prüfungsfragen mit Lösungen:
1. A customer has complained that an error message is showing up after they close and reopen the form. It is discovered that a synchronous workflow controls the error message process.
What should be changed so that the error message displays while the form is open?
A) Change the synchronous workflow to an asynchronous workflow.
B) Change the synchronous workflow to use permanent data.
C) Change the synchronous workflow to use temporary data.
D) Change the synchronous workflow to trigger from a state action.
2. When applying the Sort Section action on a form's tab, which statement is true regardless of the original layout of the sections?
A) The sections will be reorganized in the selected order with the exception of those sections where the Visible property is left unchecked.
B) The sections will be reorganized in the order that they were created.
C) The sections will be reorganized in the selected order from the top of the tab to the bottom of the tab regardless of the original parameters.
D) The sections will be reorganized in the selected order from the bottom of the tab to the top of the tab regardless of the original parameters.
3. When a transition occurs to move a record into a tri Active state, the expected behavior is that the form is in a read-only state. This is not happening. What is the issue with the Read-Only property?
A) It is not configured in the Business Object properties.
B) It is not configured in the Sub Action properties.
C) It is not configured in the State Transition properties for at least one transition.
D) It is not configured in the Form Section properties.
4. In a workflow, a Retrieve Records Task is failing to return records. Which two steps should be taken to resolve the issue? (Choose two.)
A) Make sure that the query is attached
B) Check that the filter in the query is correct
C) Check the association selected in the From Records
D) Check that the From Record is pointing to the correct workflow task
E) Run the query in the Systems Report tab of My Reports
5. Which statement is true about a Publish Name (also known as BO Mapping)?
A) A Publish Name is not required to publish a BO.
B) The Publish Name must start with a field.
C) Using multiple values for the Name field is allowed only if they come from different BO sections.
D) The Publish Name may not use multiple field values.
Fragen und Antworten:
| 1. Frage Antwort: C | 2. Frage Antwort: C | 3. Frage Antwort: C | 4. Frage Antwort: C,D | 5. Frage Antwort: B |






1219 Kundenbewertungen